- Descripción de la máquina:
- Prince Technologies PrinCe 560 Capillary Zone Electrophoresis System
- Fabricante:
- Prince Technologies
- Modelo:
- PrinCe 560
- Estado:
- usado
Precio y ubicación
VB IVA no incluído
EUR 1,470
- Ubicación:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Llamar
Detalles de la oferta
- ID del anuncio:
- A17565433
- número de referencia:
- 12878
- Actualización:
- última actualización el 21.10.2026
Descripción
Prince Technologies PrinCe 560
Capillary Zone Electrophoresis System
Connections:
Power supply, HV control, parallel connection A, parallel connection B,
serial connection A (RS232), serial connection B (RS232).
Technical Data:
Injection method: Up to 650 min, in 0.01 min steps; Hydrodynamics: 180 - 250 mbar, in 1 mbar steps, Electrokinetics: -30 to +30 kV, current and/or voltage.
Flow/Pressure range: 0 to +3000 mbar from DCI device.
Voltage range: -30 kV to +30 kV
Current range: -200uA to +200uA
Ramp: Programmable voltage or current ramp.
Bodpfou Eb D Hox Akuolp
Polarity reversal: Programmable before and during the sample run.
Autosampler: Position carousel for 30/48 sample/buffer vials. Variable vial size, including Eppendorf micro centrifuge tubes.
Buffer volume: Max. 4 ml
Sample volume: Minimum 10µl, max. 4 ml.
Temperature control: Sample and buffer 4°C to 40°C.
Capillary temperature: 5°C to below 60°C.
Detector: Allows the use of: UV/Vis, fluorescence, diode array, LIF, conductivity, electrochemical, and MS.
Year of manufacture: 2004
Model: PrinCe 560 0500.022/CR
S/N: 50-14-05-3-23
Dimensions: 50x50x54 cm
Weight: 35 kg
Without functional test.
More items - new and used - can be found in our shop!
International shipping costs on request!
El anuncio se tradujo automáticamente y se pueden haber producido errores de traducción.
Capillary Zone Electrophoresis System
Connections:
Power supply, HV control, parallel connection A, parallel connection B,
serial connection A (RS232), serial connection B (RS232).
Technical Data:
Injection method: Up to 650 min, in 0.01 min steps; Hydrodynamics: 180 - 250 mbar, in 1 mbar steps, Electrokinetics: -30 to +30 kV, current and/or voltage.
Flow/Pressure range: 0 to +3000 mbar from DCI device.
Voltage range: -30 kV to +30 kV
Current range: -200uA to +200uA
Ramp: Programmable voltage or current ramp.
Bodpfou Eb D Hox Akuolp
Polarity reversal: Programmable before and during the sample run.
Autosampler: Position carousel for 30/48 sample/buffer vials. Variable vial size, including Eppendorf micro centrifuge tubes.
Buffer volume: Max. 4 ml
Sample volume: Minimum 10µl, max. 4 ml.
Temperature control: Sample and buffer 4°C to 40°C.
Capillary temperature: 5°C to below 60°C.
Detector: Allows the use of: UV/Vis, fluorescence, diode array, LIF, conductivity, electrochemical, and MS.
Year of manufacture: 2004
Model: PrinCe 560 0500.022/CR
S/N: 50-14-05-3-23
Dimensions: 50x50x54 cm
Weight: 35 kg
Without functional test.
More items - new and used - can be found in our shop!
International shipping costs on request!
El anuncio se tradujo automáticamente y se pueden haber producido errores de traducción.
Proveedor
Nota: Regístrese gratis o inicie sesión, para ver toda la información.
Registrado desde: 2008
529 anuncios online
Enviar solicitud
Teléfono & Fax
+49 2862 ... mostrar
Su anuncio ha sido borrado con éxito
Se produjo un error