S/S LAGARDE STATIC AUTOCLAVE 4 BLAGARDE
SA
S/S LAGARDE STATIC AUTOCLAVE 4 B
LAGARDE
SA
Estado
De 2.ª mano
Ubicación
Lorquí 

Mostrar imágenes
Mostrar mapa
Datos de la máquina
- Descripción de la máquina:
- S/S LAGARDE STATIC AUTOCLAVE 4 B
- Fabricante:
- LAGARDE
- Modelo:
- SA
- Estado:
- usado
- funcionalidad:
- totalmente funcional
Precio y ubicación
- Ubicación:
- Polígono Industrial de Lorquí Parcela 129, 30564 Lorquí, ES
Llamar
Detalles de la oferta
- ID del anuncio:
- A19238281
- N.º referencia:
- 0000000197561
- Actualizado por última vez:
- el 27.05.2025
Descripción
Autoclaves are used for the sterilization of packaged products that need to reach high temperatures (+100ºC) for the elimination or inactivation of pathogenic microorganisms.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
CHARACTERISTICS:
* Forced ventilation
*Shower system.
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
Dwedpfx Abowndpljnoc
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
Static autoclaves: these are suitable for any format and are used for food packaged in cans, jars and other flexible materials.
CHARACTERISTICS:
* Forced ventilation
*Shower system.
* Temperature and time recorder.
CONSUMPTIONS:
- Steam: Maximum flow rate 2100 kg/h. Approximate consumption 475 kg/cycle.
Dwedpfx Abowndpljnoc
- Electrical energy in KW: 22kw
- Cold water in tn/hr: Flow rate 25m³/h.
- Compressed air in m³/min. The theoretical required to cool the autoclave in the worst air requirement condition (empty or with low load) is 2.91 m³/minute.
- Total amount of drainage in ton/day: Depends on the number of cycles. Approximately 0.8 m3/cycle will be drained from inside the autoclave at the end of the cycle. The water output of the exchanger will be the same as the water input during cooling, 25 m³/h.
- Total raw water consumption in tn/day: 0.8 m³/cycle final + 12-16 m³ cooling.
Documentos
Proveedor
Nota: Regístrate gratis o inicia sesión, para ver toda la información.
Registrado desde: 2024
Enviar solicitud
Teléfono & Fax
+34 968 6... mostrar
Su anuncio ha sido borrado con éxito
Se produjo un error